Mercury

MERCURY UPS 6 KVA

Application: Small network, servers and other IT
equipment
High frequency and double conversion on-line technology
Fully digitized microprocessor control
Wide input voltage range
UPS startup without battery
Cold start
Advanced battery management
Advanced battery charge in UPS off mode
Lightning and surge protection
Short circuit and surge protection
Fan speed auto control when loads varies Optional extension battery pack
Load capacity display
Smart RS232 communication with monitoring software

6,774.00

SKU: DGLMECUPS60000007 Categories: , Tags: , ,
Compare

Description

Application: Small network, servers and other IT equipment
High frequency and double conversion on-line technology
Fully digitized microprocessor control
Wide input voltage range
UPS startup without battery
Cold start
Advanced battery management
Advanced battery charge in UPS off mode
Lightning and surge protection
Short circuit and surge protection
Fan speed auto control when loads varies
Optional extension battery pack
Load capacity display
Smart RS232 communication with monitoring software
Optional SNMP Card Slot
Power: 6KVA / 4200W
Voltage range: 176 ±5VAC~276 ±5VAC
Frequency: 46~54Hz ±0.5Hz, or 56~64Hz ±0.5Hz autosensing
Input Phase: Single phase
Power factor: ≥0.98
Voltage range: 220VAC ±1%
Output Phase: Single phase
Frequency: 50Hz ±0.2% (battery mode)
THD: < 2% (Linear load); < 6% (non-linear load)
Overload: 105%~130% 10min turn to Bypass mode, > 130% 1s turn to Bypass mode
Crest factor: 3:1 (max)
Waveform: Pure sine wave
Transfer time: 0ms (AC mode – Battery mode) 0ms (AC mode – Bypass mode)
Efficiency: ≥88%
AC mode: 5 cycles turn off inverter, no transfer to Bypass, provide alarm.
Battery mode: 5 cycles turn off inverter, provide alarm.
Bypass mode: Input fuse blown or break action.
Battery Model: 12V sealed lead acid maintenance free
DC voltage: 240VDC
Configuration: 20x 12V/8.2AH
Backup time: 20min (half load) / 7min (full load)
Charge current: 1A (standard unit) / 5A (long time unit)
Recharge time: 90% capacity after 8hrs charging
Communication Interface: RS232; SNMP (optional)
Parallel Port: Parallel availability for redundancy and load sharing up to three unit
LCD Indication: Input voltage/frequency; battery voltage; output voltage/frequency; load watt/VA value & percent; inverter temperature; operation mode such as “on batt” or “on bypass”
LED Indication: Green: normal operation; Yellow: warning condition Red: abnormal operation

Brand

Mercury

Mercury

Additional information

Brand

VA

Reviews

There are no reviews yet.

Be the first to review “MERCURY UPS 6 KVA”

Your email address will not be published. Required fields are marked *